Pressure Switch
 

A Dependable Pressure-Sensing Device that Converts a set of Hydraulic Pressure to an Electrical Signal - up to THREE Signals in a Single Switch.

 

Technical Specifications:

Operating Characteristics:

  • Adjustable Range: 300 - 2,600 PSI.
  • Pressure Reset: 1125 - 300 PSI nominal.
  • Rated Pressure: 4,000 PSI.
  • Burst Pressure: 12,000 PSI.
  • Temperature Rating: -20°F to 160°F.
  • Repeatability: 2% of set pressure.

Electrical Characteristics:

  • U.L. Listed Switching Elements.
  • Rating: 4 amps, 250 VAC.  12 VDC, 3 amps.

 

 

Options:

  • Second and Third independently adjustable switches
  • Factory pre-set to specified pressures
  • 200 - 1,250 PSI range (L) (125-200 PSI reset)
  • 500 - 4,000 PSI range (H), High cycle unit (300-450 PSI reset)

Pressure Switch Wiring Instructions:

  Switch #1 Switch #2 Switch #3
Normally Open Red Red w/One Yellow Stripe Red w/Two Yellow Stripes
Common White White w/One Yellow Stripe White w/Two Yellow Stripes
Normally Closed Black Black w/One Yellow Stripe Black w/Two Yellow Stripes

Pressure Switch is tested but NOT pre-set
(Note: factory will pre-set the pressure for a nominal charge)
Important!
Lock nut torque range: 6 - 8 in. lbs.

 

1. Triple Versatility. As many as three switching elements can be independently adjusted over the full PS-400 pressure range.
2. Fluid Compatibility. Viton seal with Teflon back-up ring compatible with most hydraulic fluids.
3. Easy Pressure Adjustment. External adjustment nut is easily accessible for quick pressure resist.
4. Save Plumbing Cost. Single pressure tap (1/8" NPT female) serves all three piston mounted microswitches.
5. Oil Tight Case (NEMA 12)  - 
6. Standard Conduit Connection. 1/2" NPT female.
7. Easy Installation. Two mounting holes provided for No. 10 screws.
8. Positive Locking. Pressure Adjusting Screw.

 

How to Order:

PS-400-115 Single Switch Assembly, NEMA 12 enclosure, Vitron Seals, 300 - 2,600 PSI Range.
PS-400-215 Double Switch Assembly, NEMA 12 enclosure, Vitron Seals, 300 - 2,600 PSI Range.
PS-400-315 Triple Switch Assembly, NEMA 12 enclosure, Vitron Seals, 300 - 2,600 PSI Range.
To specify pre-set pressure(s), note setting(s) after part number.
For optional operating ranges specify (L) or (H) after part number.

 

 

 


General Information | Filler Breather Adapters | Filler Breathers
Filler Breather Accessories | Reservoir Flanges | Suction Strainers
Liquid Level Gauges | Gauge Isolators | Pressure Switch | Modular O-Ring Kit
Back to the Magnaloy Home Page

Products | Shop On-Line | Contact Us | Site Index | Site Search
Magnaloy Home Page


This Page Last modified: August 07, 2003 03:45 PM

magnaloy coupling company   P.O. Box 455 Alpena, MI 49707   989-356-2186

A Division of Douville Johnston Corporation                                                     Fax: 989-354-4190

magnaloy@magnaloy.com       sales@magnaloy.com       support@magnaloy.com     engineering@magnaloy.com      webmaster@magnaloy.com

Copyright ©1996, 1997, 1998, 1999, 2000
All Rights Reserved - Magnaloy Coupling Company

This site  maintained by Magnaloy Coupling Co